|
|
Schutzschalter Single pole thermal circuit breaker with push-to-reset, tease-free, trip-free, snap action mechanism (R-type TO CBE to EN 60934; M-type when fitted with optional manual release feature). Available in versions for plug-in or integral m
- 127-T12-H-25A
- E-T-A
-
1:
CHF 46.72
-
9Auf Lager
|
Mouser-Teilenr.
457-127-T12-H-25A
|
E-T-A
|
Schutzschalter Single pole thermal circuit breaker with push-to-reset, tease-free, trip-free, snap action mechanism (R-type TO CBE to EN 60934; M-type when fitted with optional manual release feature). Available in versions for plug-in or integral m
|
|
9Auf Lager
|
|
|
CHF 46.72
|
|
|
CHF 38.76
|
|
|
CHF 35.75
|
|
|
CHF 30.76
|
|
|
Anzeigen
|
|
|
CHF 28.84
|
|
|
CHF 26.91
|
|
Min.: 1
Mult.: 1
|
|
|
127
|
Thermal Circuit Breaker
|
Overcurrent Protection
|
25 A
|
250 VAC
|
28 VDC
|
1 Pole
|
Push to Reset
|
- 20 C
|
+ 60 C
|
Non-Illuminated
|
|
|
|
|
Schutzschalter Miniaturised single pole press-to-reset cycling trip free thermal circuit breaker designed for automotive fuse block installation. Extends the benefits of circuit breaker performance and convenience to applications which are cost cri
- 1610-H2-25A
- E-T-A
-
1:
CHF 9.66
-
259Auf Lager
|
Mouser-Teilenr.
457-1610-H2-25A
|
E-T-A
|
Schutzschalter Miniaturised single pole press-to-reset cycling trip free thermal circuit breaker designed for automotive fuse block installation. Extends the benefits of circuit breaker performance and convenience to applications which are cost cri
|
|
259Auf Lager
|
|
|
CHF 9.66
|
|
|
CHF 9.18
|
|
|
CHF 8.88
|
|
|
CHF 6.83
|
|
|
Anzeigen
|
|
|
CHF 6.21
|
|
|
CHF 5.46
|
|
|
CHF 5.12
|
|
|
CHF 5.05
|
|
|
Kostenvoranschlag
|
|
Min.: 1
Mult.: 1
|
|
|
1610
|
Miniature Circuit Breaker
|
Automotive
|
25 A
|
|
24 VDC
|
1 Pole
|
Push to Reset
|
- 40 C
|
+ 85 C
|
Non-Illuminated
|
|
|
|
|
Schutzschalter 1077, 1P, DN, 120-240VAC/80VDC, 16A
- 201-16A
- E-T-A
-
1:
CHF 38.25
-
20Auf Lager
|
Mouser-Teilenr.
457-20116
|
E-T-A
|
Schutzschalter 1077, 1P, DN, 120-240VAC/80VDC, 16A
|
|
20Auf Lager
|
|
Min.: 1
Mult.: 1
|
|
|
201
|
Thermal Circuit Breaker
|
Thermal Magnetic
|
16 A
|
240 VAC
|
65 VDC
|
1 Pole
|
Pushbutton Dual
|
- 30 C
|
+ 60 C
|
Non-Illuminated
|
|
|
|
|
Schutzschalter Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration; S-type with push-push
- 2-5700-IG1-P10-0.6A
- E-T-A
-
1:
CHF 29.37
-
8Auf Lager
|
Mouser-Teilenr.
457-25700IG1P100.6A
|
E-T-A
|
Schutzschalter Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration; S-type with push-push
|
|
8Auf Lager
|
|
|
CHF 29.37
|
|
|
CHF 28.52
|
|
|
CHF 20.74
|
|
|
CHF 19.10
|
|
|
Anzeigen
|
|
|
CHF 16.90
|
|
|
CHF 16.31
|
|
|
CHF 15.78
|
|
|
Kostenvoranschlag
|
|
Min.: 1
Mult.: 1
|
|
|
2-5700
|
Thermal Circuit Breaker
|
Overcurrent Protection
|
600 mA
|
250 VAC
|
28 VDC
|
1 Pole
|
Push to Reset
|
- 20 C
|
+ 60 C
|
Non-Illuminated
|
|
|
|
|
Schutzschalter Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration; S-typ
- 2-5700-IG2-P10-5A
- E-T-A
-
1:
CHF 26.13
-
7Auf Lager
|
Mouser-Teilenr.
457-25700IG2P105A
|
E-T-A
|
Schutzschalter Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration; S-typ
|
|
7Auf Lager
|
|
|
CHF 26.13
|
|
|
CHF 21.68
|
|
|
CHF 18.52
|
|
|
CHF 17.06
|
|
|
Anzeigen
|
|
|
CHF 15.10
|
|
|
CHF 14.57
|
|
|
CHF 14.10
|
|
|
Kostenvoranschlag
|
|
Min.: 1
Mult.: 1
|
|
|
2-5700
|
Thermal Circuit Breaker
|
Overcurrent Protection
|
5 A
|
250 VAC
|
28 VDC
|
1 Pole
|
Push to Reset
|
- 20 C
|
+ 60 C
|
Non-Illuminated
|
|
|
|
|
Schutzschalter Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration; S-typ
- 2-5700-IG2-P10-8A
- E-T-A
-
1:
CHF 26.13
-
7Auf Lager
|
Mouser-Teilenr.
457-25700IG2P108A
|
E-T-A
|
Schutzschalter Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration; S-typ
|
|
7Auf Lager
|
|
|
CHF 26.13
|
|
|
CHF 21.68
|
|
|
CHF 18.52
|
|
|
CHF 17.06
|
|
|
Anzeigen
|
|
|
CHF 15.10
|
|
|
CHF 14.57
|
|
|
CHF 14.10
|
|
|
Kostenvoranschlag
|
|
Min.: 1
Mult.: 1
|
|
|
2-5700
|
Thermal Circuit Breaker
|
Overcurrent Protection
|
8 A
|
250 VAC
|
28 VDC
|
1 Pole
|
Push to Reset
|
- 20 C
|
+ 60 C
|
Non-Illuminated
|
|
|
|
|
Schutzschalter ETA Schutzschalter
- 2-6400-IG1-L10-SI-0.3A
- E-T-A
-
1:
CHF 51.84
-
9Auf Lager
|
Mouser-Teilenr.
457-26400IG1L10SI03A
|
E-T-A
|
Schutzschalter ETA Schutzschalter
|
|
9Auf Lager
|
|
Min.: 1
Mult.: 1
|
|
|
2-6400
|
Thermal Circuit Breaker
|
Overcurrent Protection
|
300 mA
|
250 VAC
|
28 VDC
|
1 Pole
|
Push to Reset
|
- 20 C
|
+ 60 C
|
Non-Illuminated
|
|
|
|
|
Schutzschalter 1077, 1P, plug, 24VDC, Aux Cont, 3A/6A
- ESS30-S003-DC24V-3A/6A
- E-T-A
-
1:
CHF 115.38
-
2Auf Lager
|
Mouser-Teilenr.
457-30S003DC24V3A/6A
|
E-T-A
|
Schutzschalter 1077, 1P, plug, 24VDC, Aux Cont, 3A/6A
|
|
2Auf Lager
|
|
Min.: 1
Mult.: 1
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Schutzschalter The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload prot
- 3120-N321-P7T1-W12DY3-16A
- E-T-A
-
1:
CHF 41.32
-
3Auf Lager
|
Mouser-Teilenr.
457-3120N32112DY316A
|
E-T-A
|
Schutzschalter The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload prot
|
|
3Auf Lager
|
|
Min.: 1
Mult.: 1
|
|
|
3120-N
|
Thermal Circuit Breaker
|
Overcurrent Protection
|
16 A
|
115 VAC
|
50 VDC
|
2 Pole
|
Rocker
|
- 30 C
|
+ 60 C
|
Illuminated
|
|
|
|
|
Schutzschalter The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload prot
- 3120-N321-P7T1-W01D-0.5A
- E-T-A
-
1:
CHF 42.41
-
14Auf Lager
-
9Auf Bestellung
|
Mouser-Teilenr.
457-321P7T1W01D0.5A
|
E-T-A
|
Schutzschalter The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload prot
|
|
14Auf Lager
9Auf Bestellung
|
|
Min.: 1
Mult.: 1
|
|
|
3120-N
|
Thermal Circuit Breaker
|
Overcurrent Protection
|
500 mA
|
240 VAC
|
50 VDC
|
2 Pole
|
Rocker
|
- 30 C
|
+ 60 C
|
Non-Illuminated
|
|
|
|
|
Schutzschalter The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload prot
- 3120-N321-P7T1-W04L-10A
- E-T-A
-
1:
CHF 36.04
-
4Auf Lager
|
Mouser-Teilenr.
457-321P7T1W04L10A
|
E-T-A
|
Schutzschalter The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload prot
|
|
4Auf Lager
|
|
|
CHF 36.04
|
|
|
CHF 27.02
|
|
|
CHF 24.79
|
|
|
CHF 24.05
|
|
|
Anzeigen
|
|
|
CHF 21.36
|
|
|
CHF 20.98
|
|
|
CHF 20.96
|
|
|
Kostenvoranschlag
|
|
Min.: 1
Mult.: 1
|
|
|
3120-N
|
Thermal Circuit Breaker
|
Overcurrent Protection
|
10 A
|
240 VAC
|
50 VDC
|
2 Pole
|
Rocker
|
- 30 C
|
+ 60 C
|
Non-Illuminated
|
|
|
|
|
Schutzschalter The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload prot
- 3120-N321-P7T1-W04L-18A
- E-T-A
-
1:
CHF 36.04
-
7Auf Lager
|
Mouser-Teilenr.
457-321P7T1W04L18A
|
E-T-A
|
Schutzschalter The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload prot
|
|
7Auf Lager
|
|
|
CHF 36.04
|
|
|
CHF 29.90
|
|
|
CHF 24.79
|
|
|
CHF 24.05
|
|
|
Anzeigen
|
|
|
CHF 21.36
|
|
|
CHF 20.98
|
|
|
CHF 20.96
|
|
|
Kostenvoranschlag
|
|
Min.: 1
Mult.: 1
|
|
|
3120-N
|
Thermal Circuit Breaker
|
Overcurrent Protection
|
18 A
|
240 VAC
|
50 VDC
|
2 Pole
|
Rocker
|
- 30 C
|
+ 60 C
|
Non-Illuminated
|
|
|
|
|
Schutzschalter The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload prot
- 3120-N321-P7T1-W19DG3-5A
- E-T-A
-
1:
CHF 41.32
-
9Auf Lager
|
Mouser-Teilenr.
457-321P7T1W19DG35A
|
E-T-A
|
Schutzschalter The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload prot
|
|
9Auf Lager
|
|
Min.: 1
Mult.: 1
|
|
|
3120-N
|
Thermal Circuit Breaker
|
Overcurrent Protection
|
5 A
|
115 VAC
|
50 VDC
|
2 Pole
|
Rocker
|
- 30 C
|
+ 60 C
|
Illuminated
|
|
|
|
|
Schutzschalter The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload prot
- 3120-N323-P7T1-W19DG4-6A
- E-T-A
-
1:
CHF 41.32
-
5Auf Lager
|
Mouser-Teilenr.
457-323P7T1W19DG46
|
E-T-A
|
Schutzschalter The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload prot
|
|
5Auf Lager
|
|
Min.: 1
Mult.: 1
|
|
|
3120-N
|
Thermal Circuit Breaker
|
Overcurrent Protection
|
6 A
|
240 VAC
|
50 VDC
|
2 Pole
|
Rocker
|
- 30 C
|
+ 60 C
|
Illuminated
|
|
|
|
|
Schutzschalter Single pole thermal-magnetic circuit breakers with tease-free, trip-free, press-to-reset, snap action mechanism (R-type TM CBE to EN 60934; M-type with manual release (-H). Available with fast acting and standard magnetic tripping cha
- 3400-IG8-P10-6A
- E-T-A
-
1:
CHF 64.78
-
1Auf Lager
|
Mouser-Teilenr.
457-3400-IG8-P10-6A
|
E-T-A
|
Schutzschalter Single pole thermal-magnetic circuit breakers with tease-free, trip-free, press-to-reset, snap action mechanism (R-type TM CBE to EN 60934; M-type with manual release (-H). Available with fast acting and standard magnetic tripping cha
|
|
1Auf Lager
|
|
Min.: 1
Mult.: 1
|
|
|
3400
|
Thermal Circuit Breaker
|
Thermal Magnetic
|
6 A
|
240 VAC
|
65 VDC
|
1 Pole
|
Push to Reset
|
- 30 C
|
+ 60 C
|
Non-Illuminated
|
|
|
|
|
Schutzschalter Single pole thermal-magnetic circuit breakers with tease-free, trip-free, press-to-reset, snap action mechanism (R-type TM CBE to EN 60934; M-type with manual release (-H). Available with fast acting and standard magnetic tripping cha
- 3400-IG8-P10-15A
- E-T-A
-
1:
CHF 64.78
-
9Auf Lager
|
Mouser-Teilenr.
457-3400IG8P1015A
|
E-T-A
|
Schutzschalter Single pole thermal-magnetic circuit breakers with tease-free, trip-free, press-to-reset, snap action mechanism (R-type TM CBE to EN 60934; M-type with manual release (-H). Available with fast acting and standard magnetic tripping cha
|
|
9Auf Lager
|
|
Min.: 1
Mult.: 1
|
|
|
3400
|
Thermal Circuit Breaker
|
Thermal Magnetic
|
|
|
|
|
Push to Reset
|
|
|
|
|
|
|
|
Schutzschalter Single pole high performance thermal circuit breaker with tease-free, trip-free, snap action mechanism and push/pull on/off manual actuation (M-type TO CBE to EN 60934). An indicator band on the push button clearly shows the tripped/off position. Thr
- 412-K54-LN2-25A
- E-T-A
-
1:
CHF 106.25
-
3Auf Lager
-
4Auf Bestellung
|
Mouser-Teilenr.
457-412-K54-LN2-25A
|
E-T-A
|
Schutzschalter Single pole high performance thermal circuit breaker with tease-free, trip-free, snap action mechanism and push/pull on/off manual actuation (M-type TO CBE to EN 60934). An indicator band on the push button clearly shows the tripped/off position. Thr
|
|
3Auf Lager
4Auf Bestellung
|
|
Min.: 1
Mult.: 1
|
|
|
412
|
Circuit Breaker
|
Thermal
|
25 A
|
115 VAC
|
28 VDC
|
1 Pole
|
Push-Pull
|
- 55 C
|
+ 75 C
|
Non-Illuminated
|
|
|
|
|
Schutzschalter Single pole high performance thermal circuit breaker with tease-free, trip-free, snap action mechanism and push/pull on/off manual actuation (M-type TO CBE to EN 60934). An indicator band on the push button clearly shows the tripped/off position. Thr
- 413-K54-N2-30A
- E-T-A
-
1:
CHF 130.39
-
2Auf Lager
|
Mouser-Teilenr.
457-413-K54-N2-30A
|
E-T-A
|
Schutzschalter Single pole high performance thermal circuit breaker with tease-free, trip-free, snap action mechanism and push/pull on/off manual actuation (M-type TO CBE to EN 60934). An indicator band on the push button clearly shows the tripped/off position. Thr
|
|
2Auf Lager
|
|
Min.: 1
Mult.: 1
|
|
|
413
|
Thermal Circuit Breaker
|
Thermal Magnetic
|
30 A
|
|
28 VDC
|
1 Pole
|
Push-Pull
|
- 55 C
|
+ 75 C
|
Non-Illuminated
|
|
|
|
|
Schutzschalter The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload prot
- 3120-N521-P7T1-W02D-20A
- E-T-A
-
1:
CHF 36.04
-
5Auf Lager
|
Mouser-Teilenr.
457-521P7T1W02D20
|
E-T-A
|
Schutzschalter The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload prot
|
|
5Auf Lager
|
|
Min.: 1
Mult.: 1
|
|
|
3120-N
|
Thermal Circuit Breaker
|
Overcurrent Protection
|
20 A
|
240 VAC
|
50 VDC
|
2 Pole
|
Rocker
|
- 30 C
|
+ 60 C
|
Non-Illuminated
|
|
|
|
|
Schutzschalter The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload prot
- 3120-N523-P7T1-W02D-15A
- E-T-A
-
1:
CHF 36.04
-
3Auf Lager
|
Mouser-Teilenr.
457-523P7T1W02D15
|
E-T-A
|
Schutzschalter The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload prot
|
|
3Auf Lager
|
|
|
CHF 36.04
|
|
|
CHF 25.42
|
|
|
CHF 24.79
|
|
|
CHF 24.22
|
|
|
Anzeigen
|
|
|
CHF 21.42
|
|
|
CHF 21.13
|
|
|
CHF 21.09
|
|
Min.: 1
Mult.: 1
|
|
|
3120-N
|
Thermal Circuit Breaker
|
Overcurrent Protection
|
15 A
|
240 VAC
|
50 VDC
|
2 Pole
|
Rocker
|
- 30 C
|
+ 60 C
|
Non-Illuminated
|
|
|
|
|
Schutzschalter The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload protection of motors
- 3120-N523-P7T1-W02D-4A
- E-T-A
-
1:
CHF 36.04
-
2Auf Lager
|
Mouser-Teilenr.
457-523P7T1W02D4
|
E-T-A
|
Schutzschalter The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload protection of motors
|
|
2Auf Lager
|
|
|
CHF 36.04
|
|
|
CHF 25.42
|
|
|
CHF 24.79
|
|
|
CHF 24.05
|
|
|
Anzeigen
|
|
|
CHF 21.36
|
|
|
CHF 20.98
|
|
|
CHF 20.96
|
|
|
Kostenvoranschlag
|
|
Min.: 1
Mult.: 1
|
|
|
3120-N
|
Thermal Circuit Breaker
|
Overcurrent Protection
|
4 A
|
240 VAC
|
50 VDC
|
2 Pole
|
Rocker
|
- 30 C
|
+ 60 C
|
Non-Illuminated
|
|
|
|
|
Schutzschalter Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration; S-typ
- 2-5700-IG1-P10-DD-0.1A
- E-T-A
-
1:
CHF 33.62
-
14Auf Lager
-
9Auf Bestellung
|
Mouser-Teilenr.
457-5700IG1P10DD0.1A
|
E-T-A
|
Schutzschalter Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration; S-typ
|
|
14Auf Lager
9Auf Bestellung
|
|
|
CHF 33.62
|
|
|
CHF 32.68
|
|
|
CHF 20.45
|
|
|
CHF 17.34
|
|
Min.: 1
Mult.: 1
|
|
|
2-5700
|
Thermal Circuit Breaker
|
Overcurrent Protection
|
100 mA
|
250 VAC
|
28 VDC
|
1 Pole
|
Push to Reset
|
- 20 C
|
+ 60 C
|
Non-Illuminated
|
|
|
|
|
Schutzschalter Combination of single pole circuit breaker and ON/OFF switch with soft-touch rocker actuation. Contoured rockers are available with a choice of colours and legends, with optional illumination. The 3131 is sealed to provide IP66 rated
- 3131-AF1PT-000000-000-8A
- E-T-A
-
1:
CHF 23.81
-
3Auf Lager
|
Mouser-Teilenr.
457-AF1PT0000000008A
|
E-T-A
|
Schutzschalter Combination of single pole circuit breaker and ON/OFF switch with soft-touch rocker actuation. Contoured rockers are available with a choice of colours and legends, with optional illumination. The 3131 is sealed to provide IP66 rated
|
|
3Auf Lager
|
|
|
CHF 23.81
|
|
|
CHF 19.76
|
|
|
CHF 16.76
|
|
|
CHF 15.44
|
|
|
Anzeigen
|
|
|
CHF 14.76
|
|
|
CHF 14.19
|
|
|
CHF 13.70
|
|
|
Kostenvoranschlag
|
|
Min.: 1
Mult.: 1
|
|
|
3131-A/C
|
Circuit Breaker
|
Thermal
|
8 A
|
240 VAC
|
28 VDC
|
1 Pole
|
Rocker
|
- 20 C
|
+ 60 C
|
Non-Illuminated
|
|
|
|
|
Schutzschalter Combination of single pole circuit breaker and ON/OFF switch with soft-touch rocker actuation. Contoured rockers are available with a choice of colours and legends, with optional illumination. The 3131 is sealed to provide IP66 rated
- 3131-AF1PT-000000-3Y2-10A
- E-T-A
-
1:
CHF 31.92
-
6Auf Lager
|
Mouser-Teilenr.
457-AF1PT000003Y210A
|
E-T-A
|
Schutzschalter Combination of single pole circuit breaker and ON/OFF switch with soft-touch rocker actuation. Contoured rockers are available with a choice of colours and legends, with optional illumination. The 3131 is sealed to provide IP66 rated
|
|
6Auf Lager
|
|
|
CHF 31.92
|
|
|
CHF 26.48
|
|
|
CHF 22.70
|
|
|
CHF 20.93
|
|
|
Anzeigen
|
|
|
CHF 20.22
|
|
|
CHF 19.46
|
|
|
CHF 18.98
|
|
|
Kostenvoranschlag
|
|
Min.: 1
Mult.: 1
|
|
|
3131-A/C
|
Circuit Breaker
|
Thermal
|
10 A
|
|
|
1 Pole
|
Rocker
|
|
|
|
|
|
|
|
Schutzschalter 508, 1P, PL, 24VDC, N/O, RF, SF, 3A ATEX
- ESX10-103-DC24V-3A-E
- E-T-A
-
1:
CHF 90.70
-
1Auf Lager
|
Mouser-Teilenr.
457-ESX10103DC24V3AE
|
E-T-A
|
Schutzschalter 508, 1P, PL, 24VDC, N/O, RF, SF, 3A ATEX
|
|
1Auf Lager
|
|
Min.: 1
Mult.: 1
|
|
|
ESX10-E
|
Circuit Breaker
|
Electronic
|
3 A
|
|
24 VDC
|
|
Slide
|
0 C
|
+ 50 C
|
Non-Illuminated
|
|
|